INDUSTRIAL/

MODERNITY AND SIMPLICITY ARE THE KEY CHARACTERISTICS OF THIS NEUTRAL AND LINEAR CERAMIC SURFACE THAT CAN BE USED TO CREATE A GREAT EFFECT ACROSS THE DESIGN SPECTRUM, BRINGING GREAT VISUAL APPEAL TO A WIDE RANGE OF ARCHITECTURAL PROJECTS.

Certified
Quality
Learn more
INDUSTRIAL/

THE INNOVATIVE FORMAT CAN BE EMPLOYED TO MODULATE SPACE WITH A GROUND-BREAKING VISION THAT PROUDLY REVEALS ITS INSPIRATIONAL MATRIX. THE DECORATIVE TILES AND MOSAIC PATTERNS CREATE BALANCED AND ORGANIC FORMAL COMPOSITIONS DESIGNED TO SURPRISE THE OBSERVER AND EXERT IRRESISTIBLE APPEAL.

Modern design perspectives are about to change: amazing sizes, just 6 mm thick.
  • 160x320 cm
  • 80x240 cm
  • 80x80 cm
  • 80x160 cm
  • 160x160 cm
  • 120x240 cm
  • 120x120 cm
  • 60x120 cm
  • 160x320 cm
  • 80x240 cm
  • 80x80 cm
  • 80x160 cm
  • 160x160 cm
  • 120x240 cm
  • 120x120 cm
  • 60x120 cm
  • 160x320 cm
  • 80x240 cm
  • 80x80 cm
  • 80x160 cm
  • 160x160 cm
  • 120x240 cm
  • 120x120 cm
  • 60x120 cm
  • 160x320 cm
  • 80x240 cm
  • 80x80 cm
  • 80x160 cm
  • 160x160 cm
  • 120x240 cm
  • 120x120 cm
  • 60x120 cm
  • 160x320 cm
  • 80x240 cm
  • 80x80 cm
  • 80x160 cm
  • 160x160 cm
  • 120x240 cm
  • 120x120 cm
  • 60x120 cm
  • 160x320 cm
  • 80x240 cm
  • 80x80 cm
  • 80x160 cm
  • 160x160 cm
  • 120x240 cm
  • 120x120 cm
  • 60x120 cm
Print this page
Specification referenceE.N. 14411 . Appendix G. Group BⅠa. UGLTest methodReference valueDeclared value
Static coefficient of frictionASTM-C1028>0,60 dry and wet> 0,6%
MATTE
Static coefficient of friction>0,60 dry and wet> 0,6%
BUSH-HAMMERED
 
Dynamic coefficient of friction (section 9.6 ANSI A 137.1 2012)DCOF>0,42 wet >0,42 wet  
Barefoot slip resistanceDIN-51097-Classe / Class / Classe / Gruppe / Clase A+B+C
BUSH-HAMMERED
Barefoot slip resistance-Classe / Class / Classe / Gruppe / Clase A+B
MATTE
Slip resistance with shoesDIN-51130:2010-R11
BUSH-HAMMERED
Slip resistance with shoes-R10
MATTE
Slip resistance with shoes-R9
SOFT
Frost resistanceISO-10545-12Richiesta / Required / Requise / Gefordert / RequeridaRESISTE / RESISTANT / RÉSISTE / ERFÜLLT / RESISTE
Resistance to domestic chemicals and additives for swimming poolsISO-10545-13UB minimo / UB minimum / UB minimum / UB mindestens / UB minimoUA
Resistance to low concentrations of acids and alkaliCome dichiarato dal produttore / See manufacturer’s declaration / Selon déclaration du producteur / Entsprechend der Herstellerangaben / Tal como declara el fabricanteULA
Resistance to high concentrations of acids and alkaliCome dichiarato dal produttore / See manufacturer’s declaration / Selon déclaration du producteur / Entsprechend der Herstellerangaben / Tal como declara el fabricanteUHA
Resistance to stainingISO-10545-14-4 
Maximum straightness deviation, in %, in relation to the corresponding production dimensionsISO-10545-2±0,5% (±1,5 mm)± 0,10% 
Admitted deviation, in %, of the average thickness of each tile from the production dimensions±5% (±0,5 mm)± 5% 
Flatness (centre curvature / edge curvature / warpage)±0,5% (±2mm)± 0,35% 
Length and width: admitted deviation, in %, of the average size of each tile from the production dimensions±0,6% (±2 mm)± 0,15% 
Maximum right-angle deviation, in %, in relation to the corresponding production dimensions±0,5% (±2 mm)± 0,20% 
Amount of water absorbed, in percentageISO-10545-3E<0,5%average value 0,08%
Breaking strength in N (thickness >= 7,5 mm)ISO-10545-4≥1300 Newtonaverage value 3200 (sp. / thickness / ép. / Dicke / gr. 10mm) 
Bending strength in N/mm2>35 N/mm2average value 52 (sp. / thickness / ép. / Dicke / gr. 20mm)
Bending strength in N/mm2>35 N/mm2average value 50 (sp. / thickness / ép. / Dicke / gr. 10 mm)
Breaking strength in N (thickness >= 7,5 mm)≥1300 Newtonaverage value 14000 (sp. / thickness / ép. / Dicke / gr. 20mm) 
Resistance to deep abrasion of unglazed tilesISO-10545-6<175 mm3average value 140
Thermal shock resistanceISO-10545-9-RESISTE / RESISTANT / RÉSISTE / ERFÜLLT / RESISTE 

Notes

  • For optimal installation results, Florim recommends maintaining a joint of 2 mm 1/12” for single format installations and 3 mm 1/8” to combine mixed formats.

     
  • The data in the technical table does not apply to extra-large sizes. For the technical specifications of Magnum Oversize, please refer to the leaflet in “Downloads”.

     
CE Industrial
CE Industrial Magnum
GREENGUARD
LEED Industrial
LEED Industrial 20mm
LEED Industrial Magnum